Our team of experts has extensive experience in data center design, construction, and support, and we work closely with our clients to understand their business requirements and develop solutions that meet their needs. Whether you need a new data center or are looking to upgrade your existing infrastructure, we can help.
Precision Air Conditioning
Precision air conditioning is a type of cooling system used in applications that require precise control of temperature and humidity, such as data centers, server rooms, and laboratories. These systems are designed to maintain a consistent temperature and humidity level within a tight tolerance, regardless of the ambient conditions. They typically use advanced sensors, controls, and algorithms to monitor and adjust the temperature and humidity, and may incorporate features such as redundant components, fault-tolerant designs, and remote monitoring and management capabilities to ensure high availability and reliability. |
Water Leak Detection System
Water leak detection system for a data center is a critical component of the overall facility's infrastructure. It is designed to quickly detect and alert facility personnel in the event of a water leak, which can cause significant damage to sensitive IT equipment and interrupt critical operations. The system typically includes a network of water sensors placed throughout the data center, which can detect even small amounts of water or moisture. These sensors are connected to a central monitoring system, which can provide real-time alerts to facility personnel via email, text message, or other means. |
Uninterruptible Power Supply (UPS)
UPS system is an electrical device that provides emergency power to a load when the input power source, typically the mains power, fails. It is designed to protect critical equipment from power surges, voltage fluctuations, and complete power outages. The UPS system consists of a battery or a flywheel, which provides backup power when the main power source is disrupted, and an inverter, which converts the DC power from the battery into AC power for the load. |
Fire Rated Gypsum Board
Fire-rated gypsum board is a type of building material that is specifically designed to resist fire and prevent the spread of flames. It is made of gypsum and other materials that make it highly resistant to heat and flames, which makes it ideal for use in areas that require fire protection. Fire-rated gypsum board comes in a variety of thicknesses and sizes to meet different fire-resistance requirements. |
Environment Monitoring System
Environment Monitoring System for a data center is a device or a set of devices used to monitor and manage the environmental conditions in the data center. It includes sensors that measure temperature, humidity, air pressure, airflow, water leakage, and other environmental factors that can affect the performance and reliability of the data center. The system provides real-time monitoring and alerts the administrators in case of any environmental anomalies, allowing them to take appropriate actions to prevent potential downtime or damage to the IT equipment. The system can also be integrated with the building management system (BMS) to provide a centralized view of the entire facility's environmental conditions. |
Fire Door (1/2 Hours)
Fire doors are essential components of fire protection systems in data centers. They are designed to prevent the spread of fire and smoke from one part of the building to another, providing a safe escape route for occupants and protecting critical equipment and infrastructure. . |
Fire Protection System
Fire protection for data centers is essential to prevent the destruction of critical IT infrastructure and loss of data in the event of a fire. The system should be designed to quickly detect and extinguish fires while minimizing damage to the IT equipment and data. Regular testing and maintenance of the fire protection system is crucial to ensure its reliability and effectiveness. |
Raised Flooring
Raised floor for data center is a type of flooring system that elevates the computer room floor above the building's structural floor. This type of flooring allows for easy installation and maintenance of cabling, power distribution, cooling, and other systems required for a data center. It also provides ample space for air circulation, which helps in keeping the equipment cool and enhances the overall performance of the data center. Raised floors can be made of different materials, such as concrete, steel, or wood, and can be designed to support varying loads and equipment densities. |
Vesda system
VESDA (Very Early Smoke Detection Apparatus) is a type of smoke detection system commonly used in data centers. It uses laser-based air sampling technology to detect even the smallest traces of smoke before a fire can escalate, providing early warning and minimizing the potential for damage and downtime. VESDA systems are highly sensitive, reliable, and can be integrated with building automation and fire suppression systems for comprehensive fire protection. |
Electrical System
An electrical system for a data center is designed to provide reliable and uninterrupted power to critical equipment. It typically includes components such as a main distribution panel, power distribution units (PDUs), uninterruptible power supply (UPS) systems, backup generators, and automatic transfer switches (ATS). The electrical system is designed to provide redundancy and backup power in case of any outages or failures, ensuring continuous operation of critical systems. It also includes grounding and bonding systems to provide a safe and secure electrical environment for personnel and equipment. Electrical systems for data centers are typically designed and installed by electrical engineers and contractors to ensure compliance with all relevant electrical codes and standards. |